【1】Product Model(Version)

VTO1210C-X: General_VTOXXX_Eng_P_16M_SIP_V4.300.0000000.1.R.20190305

VTO2111D: General_VTO2111D_Eng_P_16M_SIP_V4.300.0000000.6.R.20190320

VTH1510CH*2: General_VTH151X_Eng_SIP_V4.300.0000000.8.R.20190316

Switch

【2】Description of the usage

Considering of Dahua VDP devices are switching to SIP2.0 solution, a lot of customers doesn’t have instruction of setting up the devices.

This guide is used for helping customers setting up the SIP2.0 firmware devices using VTO as server.

Due to the limited ability of VTO (System volume is 200VTH+10VTO+1VTS) , this solution is usually used in small apartment scenario.

【3】Basic concepts of system

  • SIP Server: Provides all services in SIP2.0 system, every device will be marked by SIP ID, in this case SIP Server is main VTO (VTO1210C-X).
  • Sub VTO: Usually used for second confirmation or open garage, in this case is VTO2111D
  • Master VTH: If one room has more than 1 VTH, there should be one master VTH, and others are Sub VTH, used for group call.
  • Sub VTH: Extensions of master VTH, all settings will copy from master VTH.
  • SIP ID: Used for marking devices in SIP2.0 system, here are examples for VTO and VTH.

                       VTO: XXXX, XXXX means VTO No.

                       VTH: YYY#Z, YYY means Room No., Z means VTH No.

                       Note: For SIP2.0 system, no matter how many VTH is used in one room, the first VTH(Master VTH)’s SIP ID must be YYY#0, and for extensions, it will be YYY#1/2/3…

【4】Solution

4.1 Preconditions:

  • Connect all devices and set the IP address properly.
  • Upgrade all devices to SIP2.0 firmware (Contact Local Technical support for latest firmware).

4.2 Step by step instructions:

4.2.1 Sub VTO Setting

  • Login the webpage of Sub VTO, in this case VTO2111D.
  • Local Setting-Basic

    Device TypeVilla Station
    Villa Call No.Room No. of VTH you want to call
    VTO No.

    SIP ID of this VTO

  • Network Setting-SIP Server



    SIP ServerDo Not Check
    Server TypeVTO
    IP Addr.

    IP Address of SIP Server (Main VTO)

    Port5060
    UsernameSIP ID of this VTO, set in Local Setting, can't change from here.
    Password123456 by default, no need to change
    SIP DomainVDP
    SIP Server UsernameUsername of SIP Server (Main VTO)
    SIP Server PasswordPassword of SIP Server (Main VTO)

4.2.2 VTH Setting


Master VTH Setting

  • VTH config

    Room No. must be YYY#0, and choose Master.

  • SIP Server

    Server IPIP address of SIP Server (Main VTO)
    Port5060
    Register Pwddefault by 123456, no need to modify.
    DomainVDP
    UsernameUsername of SIP Server (Main VTO)
    Login PwdPassword of’ SIP Server (Main VTO)
    EnableOn
  • VTO Config

    Main VTOName of Main VTO
    VTO IPIP address of Main VTO
    User NameUsername of Main VTO
    PasswordPassword of Main VTO
    Enable StatusOn
    Sub_VTO1Name of Main Sub_VTO1
    VTO IPIP address of Sub_VTO1
    User NameUsername of Sub_VTO1
    PasswordPassword of Sub_VTO1
    EnableOn

Sub VTH Setting

  • VTH Config

    Room No.YYY#1/2/3… and choose Extenion.
    Master IPIP address of Master VTH
    Master NameUser Name of master VTH, admin by default
    Master PwdPassword of Master VTH
  • SIP Server
    Automatically copy from Master VTH.
    Enable SIP Server.
  • VTO Config
    Automatically copy from Master VTH.
    Enable VTO.

4.2.3 SIP Server (Main VTO) Setting

  • Login the Server VTO, here I choose VTO1210C-X.
  • Local Setting-Basic, Set up the VTO No, disable building No. and Unit No., enable group call (used for calling room with more than 1 VTH)

    Device TypeUnit Door Station
    VTO No.

    SIP ID of this VTO

    Group CallCheck if there is extension VTH
  • Network Setting-SIP Server, enable SIP Server option, other information is not necessary to set. After ‘Save’, it will reboot.
  • Household Setting-VTO No. Management, add sub VTO to server.
    Rec No. please input VTO No. of sub VTO, and fill in the IP address, username, password and ‘save’.
  • Household Setting-Room No. Management, add VTH to server.

    Input Room No. and ‘save’, other information is not necessary.

    Note: Room No. must be XXX#0/1/2/3.

  • Household Setting-Status, Check the status of the devices.
  • Make a call test.